Free cookie consent management tool by TermsFeed

News

Home       News


Differences Between JIS Flanged Ball Valves and DIN Flanged Ball Valves

Differences Between JIS Flanged Ball Valves and DIN Flanged Ball Valves

ItemJIS Flanged Ball ValveDIN Flanged Ball Valve
Standards UsedJapanese Industrial Standards (e.g., JIS B2220, JIS 5K/10K/16K/20K)German/European standards (e.g., DIN 2501, DIN/EN 1092-1, PN10/16/25/40)
Pressure Rating FormatRated by K (kgf/cm²): 5K, 10K, 16K, etc.Rated by PN (Nominal Pressure): PN10, PN16, PN25, PN40
Flange DimensionsFollows JIS dimensional system; flange OD and bolt circle often differ from DINFollows DIN/EN 1092-1 system; generally different from JIS in all key dimensions
Bolt Pattern (Number/Size/PCD)Bolt quantity, bolt hole diameter, and pitch circle diameter differ from DIN; uses JIS bolt sizesBolt pattern defined by DIN/EN; typically incompatible with JIS bolt dimensions and spacing
InterchangeabilityCompatible only with JIS flanges; not interchangeable with DIN or ANSICompatible only with DIN/EN flanges; not interchangeable with JIS
Sealing Face TypeMostly RF (Raised Face)RF, FF (Flat Face), RTJ depending on DIN/EN standard
Typical Regions UsedJapan, Taiwan, parts of Southeast AsiaEurope, China, Russia, Middle East, and regions using EN/DIN systems